ELISA Rapid Test Kit ErgoREAD
ELISA Rapid Test Kit ErgoREAD

ELISA Rapid Test Kit ErgoREAD

Price 58000 INR/ Set

MOQ : 01 Kit

ELISA Rapid Test Kit ErgoREAD Specification

  • Automation Grade
  • Manual
  • Application
  • Qualitative detection of specific antigens/antibodies
  • Temperature
  • 2C30C (storage)
  • Equipment Type
  • ELISA Rapid Test Kit
  • Test Range
  • Qualitative detection
  • Measuring Range
  • Qualitative (Positive/Negative)
  • Features
  • Rapid result, user-friendly, minimal equipment
  • Power Supply
  • Not Required (manual kit)
  • Humidity
  • 2080% RH
  • Specimen Size
  • Typically 10100 L sample volume
  • Response Time
  • 1015 minutes
  • Number of Specimens
  • 1 per test kit
  • Display Type
  • Visual (color change/read by eye)
  • Mounting Type
  • Benchtop/portable
  • Accuracy
  • >95%
  • Usage
  • In vitro detection
  • Capacity
  • Kit available in multiple test sizes (1, 5, 10, or 25 tests)
  • Machine Weight
  • Approx. 1.5 kg
  • Test Speed
  • Results in 1015 minutes
  • Test Width
  • Not Applicable (kit format)
  • Control Mode
  • Manual
  • Packaging Type
  • Sealed pouches/box
  • Lead Time
  • Immediate/ex-stock or as per order quantity
  • Kit Contents
  • Test device/cassette, buffer/solution, sample dropper, instruction manual
  • Sample Types
  • Serum, plasma, or whole blood (depends on kit version)
  • Storage Conditions
  • 2C30C, avoid direct sunlight
  • Readout Method
  • Visual interpretation based on color change
  • Result Type
  • Qualitative, colorimetric
  • Sensitivity and Specificity
  • >95% (may vary by test)
  • Shelf Life
  • 1224 months (unopened, as per manufacturer lot)
  • Intended Use
  • Professional in vitro diagnostics
  • Disposability
  • Single-use
 
 

About ELISA Rapid Test Kit ErgoREAD

Elisa rapid test kit ErgoRead is a form of diagnostic test used to find out whether a biological sample has particular antibodies or antigens. Enzyme-linked immunosorbent assay, or ELISA, is a biochemical method for determining the presence of a certain molecule. A variety of infectious illnesses, including HIV, hepatitis B and C, and syphilis, can be quickly, accurately, and reliably detected using the Elisa rapid test kit ErgoRead. It is comprised of a sample collecting device, reagent solutions, and a test cassette, along with all other components and reagents required for the test.



Rapid and Reliable In Vitro Diagnostics

ErgoREAD ELISA Rapid Test Kit streamlines qualitative detection, empowering healthcare professionals to obtain results quickly and reliably. The user-friendly format needs no power supply and comes in a convenient sealed package, optimizing efficiency and reducing the risk of contamination. Its flexibility means it can be used on benchtops or taken to field sites. This kit enhances diagnostic workflows by providing clear results through visual color change, supporting quick decision-making for clinicians.


User-Friendly Design for Versatile Application

Each kit includes all components needed for testing, such as the test cassette, buffer, sample dropper, and step-by-step instructions. Designed for professional settings, it accommodates various sample types-serum, plasma, or whole blood-depending on the version. The disposable, single-use format ensures hygiene, and its lightweight, portable construction, combined with ambient temperature storage, makes it easy to transport and store.

FAQ's of ELISA Rapid Test Kit ErgoREAD:


Q: How do I use the ELISA Rapid Test Kit ErgoREAD?

A: To use the kit, collect the specified sample (serum, plasma, or whole blood as per the kit version), add the indicated volume (usually 10-100 L) to the test cassette, add buffer, and wait 10-15 minutes. Interpret the result visually by observing the color change, following the instructions provided in the kit manual.

Q: What sample types are compatible with the ErgoREAD kit?

A: The kit is compatible with serum, plasma, or whole blood, depending on the specific version. Please refer to the product instructions to verify which sample types are suitable for your kit.

Q: When should I read the results after applying the sample?

A: Results should be read within 10-15 minutes after applying the sample and buffer to the test cassette. Reading results outside the specified time may lead to inaccurate interpretations.

Q: Where should the test kit be stored for optimal shelf life?

A: Store the unopened kit in its sealed packaging between 2C and 30C, away from direct sunlight and at a relative humidity of 20-80%. Proper storage ensures a shelf life of 12-24 months depending on the manufacturer lot.

Q: What is the benefit of using ErgoREAD for rapid diagnostic testing?

A: ErgoREAD offers over 95% accuracy, rapid turnaround (10-15 minutes), and a user-friendly, manual format that does not require power. Its sealed, single-use design assures hygiene, while the visual colorimetric readout simplifies result interpretation for professionals.

Q: What is the process for disposing of the test kit after use?

A: After obtaining and recording the results, the test components should be disposed of as biohazardous waste according to local regulations for diagnostic materials. The kit is designed for single-use only.

Q: Can the kit be used in field or remote settings?

A: Yes, the ErgoREAD kit is manually operated, lightweight (approximately 1.5 kg), and requires no power supply, allowing it to be used effectively in both laboratory and field environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Food Testing Instruments Category

Hot Block Automated Digestion System- Vulcan

Hot Block Automated Digestion System- Vulcan

Price 2500000 INR / Piece

Minimum Order Quantity : 01 Piece

Equipment Type : Automated Hot Block Digestion System

Operating Voltage : 220240V, 5060 Hz

Temperature : Ambient to 450C

Application : Sample Digestion (Soil, Water, Food, Waste, and Biological Samples)

5 channel SPR with modular systems

5 channel SPR with modular systems

Price 5000000 INR / Piece

Minimum Order Quantity : 01 Piece

Equipment Type : 5 Channel Surface Plasmon Resonance (SPR) Modular System

Operating Voltage : 230 V AC

Temperature : Ambient +5C to 50C, precise control via inbuilt system

Application : Biomolecular interaction analysis, drug screening, immunodiagnostics

Gas Blowing Concentrators

Gas Blowing Concentrators

Price 50000 INR / Piece

Minimum Order Quantity : 01 Piece

Equipment Type : Gas Blowing Concentrator

Operating Voltage : 220 V

Temperature : 5C 40C

Application : For laboratory and industrial gas concentration testing

Shaker- Orbital Shaker

Shaker- Orbital Shaker

Price 495000 INR / Unit

Minimum Order Quantity : 01 Unit

Equipment Type : Orbital Shaker

Operating Voltage : 230V AC

Temperature : Ambient to 60C (dependent on model variant)

Application : Mixing, agitation, and aeration of samples in laboratories (biotechnology, microbiology, chemical & clinical labs)



Back to top