Gas Purification Systems
Gas Purification Systems

Gas Purification Systems

Price 1200000 INR/ Piece

MOQ : 01 Piece

Gas Purification Systems Specification

  • Response Time
  • 30 seconds
  • Test Range
  • 099.99% Purity
  • Number of Specimens
  • 14 Channels
  • Automation Grade
  • Semi-Automatic/Automatic
  • Frequency
  • 5060 Hz
  • Interface Type
  • RS232/RS485
  • Resolution
  • 0.01%
  • Specimen Size
  • Standard Gas Cylinder
  • Port Size
  • 1/4 NPT
  • Temperature
  • 5C40C
  • Equipment Type
  • Gas Purification Systems
  • Max Height
  • 1200 mm
  • Power Supply
  • 230V AC, 50Hz
  • Accuracy
  • 0.1%
  • Application
  • Removes impurities and provides pure gases for research and industrial applications
  • Display Type
  • Digital LCD
  • Mounting Type
  • Standalone, Floor-mounted
  • Humidity
  • 85% RH
  • Measuring Range
  • 0.0199.99%
  • Operating Voltage
  • 220240V AC
  • Features
  • High precision purification, modular design, corrosion-resistant
  • Gas Pressure
  • 0.10.8 MPa
  • Usage
  • Gas laboratory, industrial gas system
  • Capacity
  • Up to 20 L/min
  • Machine Weight
  • 350 kg
  • Test Speed
  • Up to 200 ml/min (adjustable)
  • Test Width
  • Standard
  • Test Stroke
  • 300 mm
  • Control Mode
  • PLC/Manual
  • Outlet Purity
  • Up to 99.999%
  • Filtration Stages
  • 3-Stage (Pre-Filter, Purification Cartridge, Final Filter)
  • Noise Level
  • 55 dB
  • Regeneration Type
  • Automatic/Manual
  • Dimensions
  • 1200 x 650 x 550 mm
  • Material
  • Stainless Steel 304/316
  • Inlet Pressure
  • 0.10.8 MPa
  • Purification Efficiency
  • >99.99%
  • Safety Features
  • Overpressure protection, Auto shut-off
 

Gas Purification Systems Trade Information

  • Minimum Order Quantity
  • 01 Piece
  • Main Domestic Market
  • All India
 

Gas Purification Systems About

The RGP series of recirculating gas purification systems are complete stand-alone systems and are the main component of any inert atmosphere gas glovebox system. It is very compact and easily fits under the antechamber or the glove box. It can achieve and maintaining a less than 1ppm H2Oand O2

Superior Purification Meets Robust Design

Engineered with high-grade stainless steel, this gas purification system ensures longevity and resistance to corrosion. Its modular design simplifies maintenance, and its multi-stage filtration eliminates impurities, achieving exceptional purity levels suitable for sensitive research and industrial processes.


Advanced Controls and Safety Features

Equipped with PLC/manual operation modes and a user-friendly digital LCD, operators can easily monitor and manage all parameters. Built-in overpressure protection and auto shut-off mechanisms provide peace of mind, safeguarding the system and users during extended operations.


Flexible Performance for Demanding Applications

With adjustable test speeds, a broad measuring range, and precise accuracy, this system adapts to diverse application needs. Supporting 1-4 specimen channels and up to 20 L/min capacity, it is ideal for laboratories and industrial environments where flexibility and quality are essential.

FAQ's of Gas Purification Systems:


Q: How does the 3-stage filtration process work in this gas purification system?

A: The 3-stage filtration sequence includes a pre-filter to capture large contaminants, followed by a purification cartridge targeting fine particles and chemical impurities, and finally a final filter to ensure gas purity exceeds 99.99%. This process ensures removal of moisture, particulates, and other trace contaminants for ultra-pure gas output.

Q: What safety features are integrated into this system to protect users and equipment?

A: The system incorporates overpressure protection and an automatic shut-off to prevent hazards caused by excessive pressure or operational issues. These features provide reliable safeguards during both manual and automated operations, ensuring safe usage in laboratory and industrial environments.

Q: When should maintenance or regeneration be performed on the purification system?

A: Regeneration can be set to occur automatically or manually based on usage and detected impurity levels. Regular maintenance schedules are recommended-typically after prolonged use or when indicated by the PLC system-to maintain optimal purification efficiency and performance.

Q: Where is this gas purification system best utilized?

A: This system is ideally suited for gas laboratories, research facilities, and industrial gas systems where high purity is essential. Its robust design and high throughput make it perfect for both distribution hubs and direct research setups across the United States.

Q: What is the installation process for this standalone, floor-mounted unit?

A: Installation is straightforward: position the system on a flat floor space, connect standard 1/4 NPT gas ports, and provide the required 220-240V AC power supply. The system's modular design ensures quick setup and integration with existing laboratory or industrial gas lines.

Q: How can users benefit from the system's automation and control features?

A: The system offers both PLC and manual control options with a digital LCD display for real-time monitoring. Users benefit from precise control over purification parameters, automated regeneration cycles, and rapid response times, enhancing workflow efficiency and data reliability.

Q: What gases and test specimen sizes is this system compatible with?

A: It accommodates standard gas cylinders as test specimens, supporting a capacity of up to 20 L/min and a variable number of channels (1-4). Its broad test range and adjustable settings ensure compatibility with a wide variety of gases used in laboratory and industrial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Testing Instruments Category

Ion Chromatography

Ion Chromatography

Minimum Order Quantity : 1 Piece

Usage : Water, food, and environmental analysis

Features : Automatic eluent generator, Inbuilt data storage, High sensitivity

Power Supply : AC 220V, 50Hz

Application : Detection and quantification of anions and cations in samples

Benchtop SPR with analysis module

Benchtop SPR with analysis module

Price 4500000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Laboratory analytical equipment

Features : Realtime kinetic analysis, temperature control module, precise liquid handling, automated sample injection

Power Supply : 100240 V AC, 50/60 Hz

Application : Biomolecular interaction analysis, binding kinetics, concentration measurement

Automatic Melting Point Apparatus

Automatic Melting Point Apparatus

Price 350000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Laboratory analysis, research, quality control

Features : Programmable ramp rate, memory storage, buzzer alarm, overtemperature protection

Power Supply : 230 V AC, 50 Hz

Application : Determination of melting points of chemicals, pharmaceuticals and other substances

Clarity Chromatography Software- calrity

Clarity Chromatography Software- calrity

Price 200000 INR / Set

Minimum Order Quantity : 01 Set

Usage : Chromatographic data management and instrument control

Features : Multiinstrument support, GLP/21 CFR Part 11 ready, data evaluation and reporting

Power Supply : PC powered (Standard AC for PC)

Application : Data acquisition, evaluation, and instrument control in chromatography



Back to top