Gas Purification Systems
Gas Purification Systems

Gas Purification Systems

Price 1200000 INR/ Piece

MOQ : 01 Piece

Gas Purification Systems Specification

  • Humidity
  • 85% RH
  • Accuracy
  • 0.1%
  • Operating Voltage
  • 220240V AC
  • Measuring Range
  • 0.0199.99%
  • Specimen Size
  • Standard Gas Cylinder
  • Gas Pressure
  • 0.10.8 MPa
  • Display Type
  • Digital LCD
  • Power Supply
  • 230V AC, 50Hz
  • Application
  • Removes impurities and provides pure gases for research and industrial applications
  • Response Time
  • 30 seconds
  • Interface Type
  • RS232/RS485
  • Max Height
  • 1200 mm
  • Temperature
  • 5C40C
  • Equipment Type
  • Gas Purification Systems
  • Mounting Type
  • Standalone, Floor-mounted
  • Features
  • High precision purification, modular design, corrosion-resistant
  • Number of Specimens
  • 14 Channels
  • Automation Grade
  • Semi-Automatic/Automatic
  • Port Size
  • 1/4 NPT
  • Test Range
  • 099.99% Purity
  • Resolution
  • 0.01%
  • Frequency
  • 5060 Hz
  • Usage
  • Gas laboratory, industrial gas system
  • Capacity
  • Up to 20 L/min
  • Machine Weight
  • 350 kg
  • Test Speed
  • Up to 200 ml/min (adjustable)
  • Test Width
  • Standard
  • Test Stroke
  • 300 mm
  • Control Mode
  • PLC/Manual
  • Regeneration Type
  • Automatic/Manual
  • Purification Efficiency
  • >99.99%
  • Material
  • Stainless Steel 304/316
  • Noise Level
  • 55 dB
  • Safety Features
  • Overpressure protection, Auto shut-off
  • Outlet Purity
  • Up to 99.999%
  • Dimensions
  • 1200 x 650 x 550 mm
  • Filtration Stages
  • 3-Stage (Pre-Filter, Purification Cartridge, Final Filter)
  • Inlet Pressure
  • 0.10.8 MPa
 

Gas Purification Systems Trade Information

  • Minimum Order Quantity
  • 01 Piece
  • Main Domestic Market
  • All India
 

About Gas Purification Systems

The RGP series of recirculating gas purification systems are complete stand-alone systems and are the main component of any inert atmosphere gas glovebox system. It is very compact and easily fits under the antechamber or the glove box. It can achieve and maintaining a less than 1ppm H2Oand O2

Superior Purification Meets Robust Design

Engineered with high-grade stainless steel, this gas purification system ensures longevity and resistance to corrosion. Its modular design simplifies maintenance, and its multi-stage filtration eliminates impurities, achieving exceptional purity levels suitable for sensitive research and industrial processes.


Advanced Controls and Safety Features

Equipped with PLC/manual operation modes and a user-friendly digital LCD, operators can easily monitor and manage all parameters. Built-in overpressure protection and auto shut-off mechanisms provide peace of mind, safeguarding the system and users during extended operations.


Flexible Performance for Demanding Applications

With adjustable test speeds, a broad measuring range, and precise accuracy, this system adapts to diverse application needs. Supporting 1-4 specimen channels and up to 20 L/min capacity, it is ideal for laboratories and industrial environments where flexibility and quality are essential.

FAQ's of Gas Purification Systems:


Q: How does the 3-stage filtration process work in this gas purification system?

A: The 3-stage filtration sequence includes a pre-filter to capture large contaminants, followed by a purification cartridge targeting fine particles and chemical impurities, and finally a final filter to ensure gas purity exceeds 99.99%. This process ensures removal of moisture, particulates, and other trace contaminants for ultra-pure gas output.

Q: What safety features are integrated into this system to protect users and equipment?

A: The system incorporates overpressure protection and an automatic shut-off to prevent hazards caused by excessive pressure or operational issues. These features provide reliable safeguards during both manual and automated operations, ensuring safe usage in laboratory and industrial environments.

Q: When should maintenance or regeneration be performed on the purification system?

A: Regeneration can be set to occur automatically or manually based on usage and detected impurity levels. Regular maintenance schedules are recommended-typically after prolonged use or when indicated by the PLC system-to maintain optimal purification efficiency and performance.

Q: Where is this gas purification system best utilized?

A: This system is ideally suited for gas laboratories, research facilities, and industrial gas systems where high purity is essential. Its robust design and high throughput make it perfect for both distribution hubs and direct research setups across the United States.

Q: What is the installation process for this standalone, floor-mounted unit?

A: Installation is straightforward: position the system on a flat floor space, connect standard 1/4 NPT gas ports, and provide the required 220-240V AC power supply. The system's modular design ensures quick setup and integration with existing laboratory or industrial gas lines.

Q: How can users benefit from the system's automation and control features?

A: The system offers both PLC and manual control options with a digital LCD display for real-time monitoring. Users benefit from precise control over purification parameters, automated regeneration cycles, and rapid response times, enhancing workflow efficiency and data reliability.

Q: What gases and test specimen sizes is this system compatible with?

A: It accommodates standard gas cylinders as test specimens, supporting a capacity of up to 20 L/min and a variable number of channels (1-4). Its broad test range and adjustable settings ensure compatibility with a wide variety of gases used in laboratory and industrial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Testing Instruments Category

SS Glovebox Systems

SS Glovebox Systems

Price 700000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Controlled atmosphere work, handling sensitive materials

Features : Leaktight design, modular, customizable ports

Control Mode : Digital PLC or Manual

Power Supply : 220V/50Hz single phase or 110V/60Hz

Freeze Dryer Bench Top and Floor Types

Freeze Dryer Bench Top and Floor Types

Price 950000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Lab, Industrial

Features : Stainless Steel Chamber, Transparent Door, Portable Construction

Control Mode : Microprocessor based with LCD display

Power Supply : 220V/50Hz (Bench Top), 380V/50Hz (Floor Type)

Amino Acid Analyzer System

Amino Acid Analyzer System

Price 3800000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Amino acid profile determination

Features : High sensitivity, Autosampling, Builtin printer, Multiple detection modes, Userfriendly software

Control Mode : Microprocessor / PC based

Power Supply : AC 220V 10%, 50/60Hz

Touchscreen Spectrophotometer

Touchscreen Spectrophotometer

Price 900000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Absorbance, Transmittance, Quantitative analysis

Features : Graphical display, Auto calibration, Data storage, USB export

Control Mode : Touchscreen interface

Power Supply : AC 220V/50Hz



Back to top