GPC For Pesticide Residue Sample Cleanup
GPC For Pesticide Residue Sample Cleanup

GPC For Pesticide Residue Sample Cleanup

MOQ : 1 Piece

GPC For Pesticide Residue Sample Cleanup Specification

  • Accuracy
  • High recovery, >90%
  • Display Type
  • Digital/Analog options
  • Max Height
  • 500 mm
  • Automation Grade
  • Semi-automatic
  • Interface Type
  • User-friendly control panel
  • Power Supply
  • 220 V AC, 50 Hz
  • Port Size
  • Compatible with standard glass columns
  • Features
  • Easy operation, high recovery, robust glassware, chemical resistant
  • Resolution
  • Precise fraction selection (1 ml)
  • Frequency
  • 50 Hz
  • Number of Specimens
  • 1-6 per batch
  • Application
  • Sample cleanup for pesticide residue analysis
  • Gas Pressure
  • 0.1-0.5 MPa (as required)
  • Equipment Type
  • Gel Permeation Chromatography (GPC) Clean-up System
  • Operating Voltage
  • 220 V AC
  • Mounting Type
  • Bench-top
  • Humidity
  • 30-80% RH
  • Specimen Size
  • up to 1 g
  • Temperature
  • 15-35°C
  • Test Range
  • Suitable for various pesticide residues in food and environmental samples
  • Measuring Range
  • Up to 250 ml sample volume
  • Response Time
  • < 2 min per step
  • Usage
  • Laboratory sample cleanup
  • Capacity
  • Standard and customizable as per requirement
  • Machine Weight
  • Approx. 20-25 kg
  • Test Speed
  • Manual/Up to 10 ml/min
  • Test Width
  • Standard
  • Test Stroke
  • 50-300 mm (adjustable)
  • Control Mode
  • Manual and Programmable
  • Package Contents
  • Main unit, GPC column, fraction collector tubes, user manual
  • Waste Collection
  • Integrated waste container
  • Cleaning Method
  • Easy disassembly and cleaning
  • Column Dimensions
  • 30 mm 600 mm (standard)
  • Solvent Compatibility
  • Works with cyclohexane, ethyl acetate, acetone, hexane, DCM, etc.
  • Material of Construction
  • High-quality borosilicate glass and PTFE fittings
  • Safety Protection
  • Over-pressure and leak protection system
 

GPC For Pesticide Residue Sample Cleanup Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Week
  • Delivery Time
  • 30 Days
  • Main Domestic Market
  • All India, Karnataka
 

About GPC For Pesticide Residue Sample Cleanup

Our company has sculpted a remarkable place in the market as a reputed supplier of GPC For Pesticide Residue Sample Cleanup. This equipment is used for herbicide and pesticide residues analysis purpose. We source this equipment from the trusted vendors of the market with the help of our agents. It is an automated sample preparation solution for accelerated solvent extraction platform. GPC For Pesticide Residue Sample Cleanup is used in food and pharmaceutical laboratory. Clients can avail our testing equipments in different specifications as per their requirements.

Features:

  • Isolates trace organics from large volume matrices
  • High sample throughput
  • Reduced labor and bench space




Advanced Construction and Safety

Engineered with high-grade borosilicate glass and PTFE fittings, the GPC system ensures chemical resistance and durability. The over-pressure and leak protection system safeguards laboratory operations, making this equipment reliable for frequent use. Integrated safety and waste collection features enhance environmental and user safety.


Versatile Solvent Compatibility

This GPC Clean-up System is compatible with popular solvents such as cyclohexane, ethyl acetate, acetone, hexane, and DCM. Its robust materials resist corrosion and chemical degradation, allowing for flexible method development and consistent results across various sample matrices.


User-Friendly Control and Maintenance

The equipment features manual and programmable control modes, a user-friendly digital or analog display, and simplified disassembly for cleaning. These functions enable efficient operation, quick adaptation to different test protocols, and minimal downtime during maintenance or specimen changes.


Optimized for Laboratory Productivity

Capable of processing up to six specimens per batch, with up to 1 g sample size and high sample recovery rates, this GPC system streamlines pesticide residue analysis. Its bench-top mounting and semi-automatic operation help maximize throughput while maintaining precise fraction selection for reliable data collection.

FAQs of GPC For Pesticide Residue Sample Cleanup:


Q: How does the GPC Clean-up System enhance pesticide residue analysis?

A: The system provides precise fraction selection and high recovery rates (>90%), ensuring contaminants are efficiently separated from target analytes. Its advanced features increase the reliability and accuracy of results in food and environmental sample testing.

Q: What materials are used in constructing the GPC column?

A: The column is crafted from high-quality borosilicate glass, with PTFE fittings, offering excellent chemical resistance and ensuring durability for repeated laboratory use.

Q: When should the GPC Clean-up System be used in pesticide analysis?

A: It is best utilized during the sample cleanup phase before chromatographic or mass spectrometry measurement, effectively removing interfering substances and improving analysis quality.

Q: Where can the GPC Clean-up System be installed?

A: Designed for bench-top use, it fits seamlessly into standard laboratory setups. Its compact design and integrated waste container make it suitable for food safety labs, environmental monitoring facilities, and research institutes.

Q: What is the process for cleaning and maintaining the GPC system?

A: The equipment offers easy disassembly and cleaning, utilizing its robust glass and PTFE components. Routine maintenance involves simple rinsing of the column and fittings, enhancing longevity and reducing contamination risks.

Q: How many specimens can be processed at once?

A: The system can handle 16 specimens per batch, with individual specimen sizes up to 1 g. This facilitates batch processing for greater laboratory productivity.

Q: What are the key benefits of using this GPC Clean-up System?

A: Key advantages include efficient sample cleanup, high recovery rates, precise control, solvent versatility, robust chemical resistance, and reliable safety features, all contributing to faster, more accurate pesticide residue analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Food Testing Instruments Category

Fully Automated Sample Preparation System Quechers

Fully Automated Sample Preparation System Quechers

Minimum Order Quantity : 1 Piece

Application : Residue Analysis, Food Safety, Laboratory Use

Equipment Type : Fully Automated Quechers Sample Preparation System

Capacity : 8 or 16 sample tubes

Automation Grade : Fully Automatic

5 channel SPR with modular systems

5 channel SPR with modular systems

Price 5000000 INR / Piece

Minimum Order Quantity : 01 Piece

Application : Biomolecular interaction analysis, drug screening, immunodiagnostics

Equipment Type : 5 Channel Surface Plasmon Resonance (SPR) Modular System

Capacity : Up to 5 analytes per run

Automation Grade : Automatic

High Performance Liquid Chromatography (HPLC) SYSTEMS

High Performance Liquid Chromatography (HPLC) SYSTEMS

Price 800000 INR / Set

Minimum Order Quantity : 01 Set

Application : Pharmaceutical, Analytical, Environmental, Food & Beverage Testing

Equipment Type : High Performance Liquid Chromatography (HPLC) System

Capacity : Single or dual channel configuration

Automation Grade : Semiautomatic / Fully automatic

Pump for Post Column Derivatization Systems

Pump for Post Column Derivatization Systems

Price 100000 INR / Unit

Minimum Order Quantity : 01 Unit

Application : HPLC PostColumn Reaction Systems, Analytical Chemistry

Equipment Type : Post Column Derivatization Pump

Capacity : 0.0110 mL/min flow rate

Automation Grade : Semiautomatic / Automatic (optional)



Back to top