Kjeldahl Nitrogen Analyzer
Kjeldahl Nitrogen Analyzer

Kjeldahl Nitrogen Analyzer

Price 700000 INR/ Number

MOQ : 01 Number

Kjeldahl Nitrogen Analyzer Specification

  • Operating Voltage
  • 220V AC
  • Response Time
  • Within 10 min per analysis
  • Display Type
  • Digital LCD
  • Features
  • Automatic distillation and titration, programmable settings, safety protection
  • Gas Pressure
  • 0.6-0.8 MPa (for steam generator)
  • Measuring Range
  • 0.1 mg - 200 mg N
  • Application
  • Determination of Nitrogen/Protein content in food, feed, fertilizer, etc.
  • Equipment Type
  • Kjeldahl Nitrogen Analyzer
  • Interface Type
  • RS232/USB
  • Humidity
  • 85% RH
  • Accuracy
  • 1% deviation
  • Number of Specimens
  • 1 per test cycle
  • Test Range
  • 0.1 mg - 200 mg Nitrogen
  • Max Height
  • 520 mm
  • Power Supply
  • 220V AC, 50Hz
  • Temperature
  • 10C - 35C
  • Resolution
  • 0.1 mg N
  • Frequency
  • 50 Hz
  • Mounting Type
  • Bench-top
  • Specimen Size
  • Typically 0.5 g 5 g (sample dependent)
  • Automation Grade
  • Fully automatic
  • Port Size
  • Standard fittings
  • Usage
  • Laboratory quantitative nitrogen analysis
  • Capacity
  • Up to 300 ml digestion tube
  • Machine Weight
  • 35 kg
  • Control Mode
  • Automatic
  • Safety Functions
  • Over-temperature shutdown, automatic cooling, leakage detector, safety door
  • Heating System
  • Infrared heater or block digestion
  • Physical Dimensions
  • Approx. 50 x 45 x 35 cm (L x W x H)
  • Data Storage
  • Built-in memory for up to 1000 test results
  • Distillation Volume
  • Up to 100 ml per test
  • Sample Throughput
  • Up to 60 samples per day (depends on workflow)
  • Fume Handling
  • Integrated fume neutralization system
  • Calibration
  • Automatic and manual calibration supported
  • Water Consumption
  • Approx. 2 L/min during distillation
  • Reagent Dispenser
  • Automated reagent addition
  • Cleaning Method
  • Automatic tube cleaning and rinsing
  • Chemical Compatibility
  • Compatible with concentrated acids and alkalis
 
 

About Kjeldahl Nitrogen Analyzer

Kjeldahl Analyzer

Kjeldahl Analyzer is an automatic device integrating distillation and titration functions designed based on classic Kjeldahl nitrogen determination method. Used in Widely used in the fields of food processing, feed production, tobacco, animal husbandry, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality supervision, other fields of nitrogen or protein determination.



Efficient High-Throughput Nitrogen Analysis

Capable of analyzing up to 60 samples per day, this Kjeldahl Nitrogen Analyzer significantly enhances laboratory productivity. Its robust automation supports consistent, reliable nitrogen and protein determination in varied sample types, helping users achieve rapid, repeatable results.


Advanced Safety & Automation Features

The analyzer prioritizes user safety and convenience with automated distillation, titration, and tube cleaning. Safety mechanisms such as over-temperature shutdown, automatic cooling, leakage detection, and a safety door ensure risk-free operation, even with concentrated acids or alkalis.


Enhanced Data Management and Compatibility

Equipped with a digital LCD display and memory for up to 1,000 results, the instrument enables straightforward data retrieval and report generation. RS232/USB interfaces ensure seamless connectivity, while flexible calibration options keep the analyzer tuned for accuracy.

FAQs of Kjeldahl Nitrogen Analyzer:


Q: How does the Kjeldahl Nitrogen Analyzer automate the nitrogen analysis process?

A: The analyzer automates the entire nitrogen analysis workflow, including sample digestion with infrared or block heating, automatic distillation and titration, reagent dispensing, and tube cleaning. This ensures consistent and accurate results while reducing manual intervention.

Q: What types of samples and applications is this equipment suitable for?

A: It is designed for the quantitative determination of nitrogen and protein in a broad range of matrices, including food, feed, fertilizers, and other agricultural and environmental samples, making it ideal for laboratory and industrial quality control.

Q: When should calibration of the Kjeldahl Analyzer be performed and what methods are available?

A: Calibration should be performed during initial setup, after maintenance, or whenever accuracy verification is required. The analyzer supports both automatic and manual calibration methods to ensure precise and reliable measurements.

Q: Where can this analyzer be installed and what are its space requirements?

A: With compact dimensions of approximately 50 x 45 x 35 cm and a bench-top mounting type, the analyzer is suitable for most laboratory environments in the United States. Ensure installation in controlled conditions (10C35C, 85% RH) and a power supply of 220V AC, 50Hz.

Q: What are the key safety features incorporated in this analyzer?

A: Essential safety functions include over-temperature shutdown, automatic cooling, leakage detection, a safety door, and an integrated fume neutralization system. These features protect users when working with concentrated acids and alkalis during analysis.

Q: How is data managed and stored in this system?

A: The analyzer can store up to 1,000 test results in its built-in memory. Results can be retrieved via its digital LCD interface and exported using RS232 or USB connections, facilitating efficient data handling and traceability.

Q: What are the benefits of using this fully automatic analyzer for nitrogen determination?

A: Users benefit from enhanced throughput, reduced operational errors, built-in safety, automated cleaning and reagent handling, and precise measurement with 1% deviation. These advantages streamline laboratory workflows and support consistent, high-quality analytical results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Food Testing Instruments Category

Hot Block Automated Digestion System- Vulcan

Hot Block Automated Digestion System- Vulcan

Price 2500000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Laboratory Digestion Process

Port Size : 12, 25, or 54 positions (blocks)

Mounting Type : Benchtop

Power Supply : 230V AC, 50/60Hz

Gas Blowing Concentrators

Gas Blowing Concentrators

Price 50000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Continuous or batch testing

Port Size : 1/2 inch BSP

Mounting Type : Tabletop

Power Supply : 220 V AC, 50 Hz

Automated Sample Digestion System- Nitron

Automated Sample Digestion System- Nitron

Price 2500000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Laboratory/Research/Industrial

Port Size : Standard digestion tubes OD 42mm

Mounting Type : Benchtop

Power Supply : 230V AC, 50/60 Hz

Pump for Post Column Derivatization Systems

Pump for Post Column Derivatization Systems

Price 100000 INR / Unit

Minimum Order Quantity : 01 Unit

Usage : Continuous liquid delivery for postcolumn chemical derivatization

Port Size : 1/16 inch or as per request

Mounting Type : Benchtop

Power Supply : 230V AC, 5060Hz



Back to top