Automated Sample Digestion System- Nitron
Automated Sample Digestion System- Nitron

Automated Sample Digestion System- Nitron

Price 2500000 INR/ Piece

MOQ : 01 Piece

Automated Sample Digestion System- Nitron Specification

  • Features
  • Preset programs, programmable temperature profile, higher safety & corrosion resistance, auto-lift mechanism, acid-resistant construction, exhaust system
  • Specimen Size
  • Digestion tube volume: 250 ml & 100 ml
  • Automation Grade
  • Fully Automatic
  • Hardness
  • Corrosion-resistant body
  • Mounting Type
  • Benchtop
  • Port Size
  • Standard digestion tubes OD 42mm
  • Resolution
  • 1C
  • Number of Specimens
  • 6, 8 & 12-place configurations
  • Frequency
  • 50/60 Hz
  • Operating Voltage
  • 230V AC
  • Response Time
  • Instant feedback (alarm/alerts)
  • Gas Pressure
  • Required exhaust extraction, negative pressure @ 12 m3/h
  • Power Supply
  • 230V AC, 50/60 Hz
  • Max Height
  • 450 mm (with open hood)
  • Application
  • Acid digestion of samples for Kjeldahl, heavy metals, environmental, agricultural, food & pharma analysis
  • Display Type
  • Digital display with touchscreen interface
  • Equipment Type
  • Automated Sample Digestion System
  • Interface Type
  • USB & Ethernet connectivity
  • Humidity
  • 85% RH
  • Temperature
  • Ambient +5C to 40C
  • Accuracy
  • 1C temperature uniformity
  • Usage
  • Laboratory/Research/Industrial
  • Capacity
  • 6/8/12 samples per batch
  • Machine Weight
  • Approx. 45 kg
  • Control Mode
  • Microprocessor based Automatic Control
  • Safety Features
  • Over temperature protection, automatic shut-off, safety shield, and error alarm
  • Material of Construction
  • Epoxy powder-coated mild steel body, acid-proof PTFE lining
  • Fume Dissipation
  • Integrated fume suction & exhaust for operator safety
  • Software Support
  • Customizable and upgradable software for digestion protocols
  • Heater Type
  • Infrared/ceramic block heaters
  • Accessories Included
  • Starter digestion tubes, exhaust pipe, holder, user manual
  • Timer Function
  • Programmable up to 9 hours
  • Program Memory
  • 10 user-programmable memory slots
  • Heating Rate
  • Up to 30C per minute
 
 

About Automated Sample Digestion System- Nitron



Capitalise on the finest advancements in sample preparation with the Automated Sample Digestion System - Nitron, an eminent solution ending soon in limited supply. Engineered with noteworthy features such as infrared/ceramic block heaters, programmable timer, and advanced safety shield, it delivers up to 12 samples per batch efficiently. Its integrated fume suction, PTFE lining, and epoxy-coated steel body ensure exceptional safety and corrosion resistance. A fully automatic microprocessor control and customizable software enhance user flexibility, solidifying Nitron's place among the freshest laboratory innovations for digestion protocols and precise analyses.

Automated Sample Digestion System- Nitron: Usage Directions & Profile

To operate the Nitron, users simply select preset or programmable protocols via the touchscreen digital display. Ideal for laboratory, research, and industrial settings, this fully automatic benchtop system is designed for acid digestion of samples in applications covering environmental, agricultural, food, pharma, and heavy metal analysis. Used primarily by laboratory technicians and researchers, this unit accommodates 6, 8, or 12 specimens, providing both accuracy and safety for professional sample digestion needs.


Automated Sample Digestion System- Nitron: Export Market & Payment Logistics

Experience express shipping and efficient freight handling when ordering the Nitron for export or domestic laboratory outfitting. Samples are available upon request, supporting an informed purchase process. We serve the export market globally, particularly importers, wholesalers, and distributors in Canada. Secure packaging ensures safety during transit, with each unit carefully boxed alongside included accessories. Payment terms are flexible and designed to streamline transactions for our eminent customers, ensuring a smooth procurement experience.


FAQ's of Automated Sample Digestion System- Nitron:


Q: How does the Nitron ensure operator safety during sample digestion?

A: The Nitron is equipped with over temperature protection, automatic shut-off, a safety shield, error alarm system, and an integrated fume suction and exhaust, providing comprehensive safety for operators throughout the digestion process.

Q: What are the primary applications for the Nitron Automated Sample Digestion System?

A: This system is designed for acid digestion of samples in protocols such as Kjeldahl analysis, heavy metals, environmental monitoring, agricultural tests, and food and pharmaceutical analyses.

Q: How many samples can the Nitron process in a single batch?

A: The Nitron supports 6, 8, or 12-place specimen configurations, accommodating up to 12 samples per batch with digestion tube volumes of 250 ml or 100 ml.

Q: What is the process for programming and storing custom digestion routines in the Nitron?

A: Users can program up to 10 custom digestion protocols using the microprocessor-based touchscreen display, and these routines are easily accessible for future use via the machine's memory slots.

Q: Where is the Nitron most beneficially used, and by whom?

A: The Nitron is most beneficial in laboratories, research institutions, and industrial environments, primarily operated by laboratory technicians, analysts, and scientific researchers.

Q: What advantages does the Nitron offer for international distributors and importers?

A: The Nitron offers express shipping, robust packaging, and flexible payment terms tailored for export markets and distributors.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Food Testing Instruments Category

Gas Blowing Concentrators

Gas Blowing Concentrators

Price 50000 INR / Piece

Minimum Order Quantity : 01 Piece

Power Supply : 220 V AC, 50 Hz

Temperature : 5C 40C

Accuracy : 2%

Control Mode : Manual/Automatic

High Performance Liquid Chromatography (HPLC) SYSTEMS

High Performance Liquid Chromatography (HPLC) SYSTEMS

Price 800000 INR / Set

Minimum Order Quantity : 01 Set

Power Supply : 220V, 50/60Hz AC

Temperature : Ambient, with optional Column Oven 10C to 60C

Accuracy : 0.1% of set value

Control Mode : Microprocessor / Computer Controlled

Touch Screen Spectrophotometer-TSS

Touch Screen Spectrophotometer-TSS

Price 250000 INR / Piece

Minimum Order Quantity : 01 Piece

Power Supply : AC 220V, 50Hz

Temperature : 10C 40C

Accuracy : 0.1% Transmittance

Control Mode : Touch Screen Control

ELISA Rapid Test Kit ErgoREAD

ELISA Rapid Test Kit ErgoREAD

Price 58000 INR / Set

Minimum Order Quantity : 01 Kit

Power Supply : Not Required (manual kit)

Temperature : 2C30C (storage)

Accuracy : >95%

Control Mode : Manual



Back to top