Gas Purification System
Gas Purification System

Gas Purification System

Price 1200000 INR/ Piece

MOQ : 01 Piece

Gas Purification System Specification

  • Frequency
  • 50/60 Hz
  • Operating Voltage
  • 220-240V AC
  • Equipment Type
  • Gas Purification System
  • Response Time
  • <10 sec (measurement devices only)
  • Humidity
  • 5%-85% RH (non-condensing operational environment)
  • Accuracy
  • 1% of full scale
  • Port Size
  • 1/4 to 1 NPT/BSP (customizable)
  • Temperature
  • 5C 40C (operating range)
  • Mounting Type
  • Skid mounted/Floor mounted
  • Resolution
  • 0.01% (purity metering)
  • Features
  • Modular design, easy maintenance, high efficiency, filter replacement indicators, automatic purge, corrosion-resistant material
  • Automation Grade
  • Semi-Automatic / Fully Automatic (as configured)
  • Max Height
  • 1200-2100 mm (varies per system capacity)
  • Application
  • Removal of moisture, oil, oxygen, hydrocarbons, and other contaminants from industrial gases
  • Measuring Range
  • 099.99% Purity (Gas dependent)
  • Power Supply
  • 220-240V AC, 50/60 Hz, Single Phase
  • Interface Type
  • RS-485/Analog output (optional)
  • Display Type
  • Digital LCD/LED display
  • Gas Pressure
  • 0.1 10 bar (as per user requirement)
  • Usage
  • Industrial gas purification (nitrogen, hydrogen, argon, oxygen, etc.)
  • Capacity
  • 10-200 Nm/hr (based on system design)
  • Machine Weight
  • Approx. 100-250 kg (varies by model complexity)
  • Control Mode
  • Automatic / Manual (via PLC or touch panel)
  • Purification Stages
  • Multi-stage (Pre-filter, Activated Carbon, Molecular Sieve, etc.)
  • Ambient Operating Conditions
  • Indoor, dust-free environment
  • Safety Features
  • Pressure relief valves, emergency shutdown, leak detection
  • Compliance Standards
  • ISO, CE, applicable industry standards
  • Outlet Gas Purity
  • Up to 99.999% (based on application)
  • Inlet Gas Types
  • Nitrogen, Hydrogen, Oxygen, Argon, Helium, Compressed Air
  • Maintenance Requirements
  • Low, periodic filter/adsorbent media replacement
  • Operating Principle
  • Adsorption, Filtration, and Catalytic Reactions
  • Color/Finish
  • Standard industrial grey/optional custom colors
  • Installation Service
  • Available on request
  • Noise Level
  • <75 dB(A) at 1 meter
  • Material of Construction
  • SS304/SS316 for wetted parts
 
 

Gas Purification System About

Gas Purification Systems

The RGP series of recirculating gas purification systems are complete stand-alone systems and are the main component of any inert atmosphere gas glovebox system. It is very compact and easily fits under the antechamber or the glove box.

It can achieve and maintaining a less than 1ppm H2O and O2



Advanced Multi-Stage Purification

Each gas purification system incorporates sequential stages-including pre-filtration, activated carbon treatment, and molecular sieve adsorption-to efficiently eliminate moisture, oils, hydrocarbons, and oxygen from process gases. This comprehensive approach ensures exceptional gas purity, supporting critical industrial applications requiring contamination control.


High Purity & Broad Compatibility

Delivering up to 99.999% outlet purity, this equipment is compatible with a range of gases such as nitrogen, hydrogen, oxygen, argon, helium, and compressed air. Suitable for industries where ultra-high purity is essential, the system accurately monitors purity with a digital LCD/LED display, enabling reliable quality assurance.


Compliance, Safety, and Ease of Use

Designed for strict compliance with ISO, CE, and applicable standards, the system includes safety features such as pressure relief valves, emergency shutdown, and leak detection. The modular configuration, low maintenance requirements, filter replacement indicators, and user-friendly automatic/manual controls ensure safe, reliable, and efficient operation.

FAQ's of Gas Purification System:


Q: How does the gas purification system remove contaminants from industrial gases?

A: The system uses a multi-stage process involving pre-filtration to capture particulates, activated carbon to trap oil and hydrocarbons, and molecular sieves for moisture adsorption. Additional catalytic and filtration steps further enhance purity, resulting in gas outlet purities up to 99.999%.

Q: What types of gases can be purified using this system?

A: This purification system is engineered to handle nitrogen, hydrogen, oxygen, argon, helium, and compressed air. It's adaptable to various industrial processes requiring specific gas qualities.

Q: When should maintenance be performed, and what does it involve?

A: Maintenance is straightforward and infrequent, requiring periodic replacement of filters and adsorbent media. Indicator alerts are integrated for timely servicing, and the equipment's low-maintenance design keeps downtime minimal.

Q: Where is the optimal installation site for this purification system?

A: For best results and longevity, install the gas purification system indoors in a dust-free environment. This ensures stable operation, accurate measurements, and reduces the risk of environmental interference.

Q: What is the benefit of using SS304/SS316 for wetted parts?

A: SS304/SS316 stainless steel offers excellent corrosion resistance and durability, especially when exposed to high-purity gases. This ensures the integrity of purified gas and extends the service life of the purification system.

Q: How is gas purity measured and displayed by the system?

A: Purity is monitored with integrated sensors and relayed to a digital LCD or LED display. The measurement devices have an accuracy of 1% of full scale, 0.01% resolution, and display results in less than 10 seconds, allowing for quick verification of gas quality.

Q: What are the advantages of the system's automatic and manual control options?

A: Users can operate the system in automatic mode for efficiency or select manual mode for customized control via PLC or touch panel. This flexibility aligns with varying process needs, offering both hands-off operation and precise manual adjustments as required.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Research/ Institutional Instrument Category

Glove Box System

Glove Box System

Price 2100000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Touch Screen PLC Control

Usage : Controlled Atmosphere Handling

Features : Air tight, Anticorrosive, Transparent window, Automatic purge

Automation Grade : SemiAutomatic

Colony Quant Automated colony counter

Colony Quant Automated colony counter

Price 1250000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Touch screen control, automated operation

Usage : Laboratory automation, colony count validation

Features : Autocount, traceable data export, adjustable light source, user calibration

Automation Grade : Fully automatic

Surface Plasma Resonance SPRm 200S

Surface Plasma Resonance SPRm 200S

Price 4500000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Touch Screen / Computer Software

Usage : Laboratory analytical measurement

Features : Realtime imaging, kinetic analysis, labelfree quantification

Automation Grade : Semiautomatic

High Speed Table Top and Floor Standing Centrifuges

High Speed Table Top and Floor Standing Centrifuges

Price 350000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Microprocessorbased programmable control

Usage : High speed sample separation & analysis

Features : Imbalance detection, automatic lid lock, programmable memory, brushless motor

Automation Grade : SemiAutomatic



Back to top