Gas Purification System
Gas Purification System

Gas Purification System

Price 1200000 INR/ Piece

MOQ : 01 Piece

Gas Purification System Specification

  • Gas Pressure
  • 0.1 10 bar (as per user requirement)
  • Frequency
  • 50/60 Hz
  • Response Time
  • <10 sec (measurement devices only)
  • Application
  • Removal of moisture, oil, oxygen, hydrocarbons, and other contaminants from industrial gases
  • Mounting Type
  • Skid mounted/Floor mounted
  • Features
  • Modular design, easy maintenance, high efficiency, filter replacement indicators, automatic purge, corrosion-resistant material
  • Temperature
  • 5C 40C (operating range)
  • Port Size
  • 1/4 to 1 NPT/BSP (customizable)
  • Display Type
  • Digital LCD/LED display
  • Measuring Range
  • 099.99% Purity (Gas dependent)
  • Equipment Type
  • Gas Purification System
  • Automation Grade
  • Semi-Automatic / Fully Automatic (as configured)
  • Accuracy
  • 1% of full scale
  • Humidity
  • 5%-85% RH (non-condensing operational environment)
  • Resolution
  • 0.01% (purity metering)
  • Interface Type
  • RS-485/Analog output (optional)
  • Power Supply
  • 220-240V AC, 50/60 Hz, Single Phase
  • Max Height
  • 1200-2100 mm (varies per system capacity)
  • Operating Voltage
  • 220-240V AC
  • Usage
  • Industrial gas purification (nitrogen, hydrogen, argon, oxygen, etc.)
  • Capacity
  • 10-200 Nm/hr (based on system design)
  • Machine Weight
  • Approx. 100-250 kg (varies by model complexity)
  • Control Mode
  • Automatic / Manual (via PLC or touch panel)
  • Outlet Gas Purity
  • Up to 99.999% (based on application)
  • Color/Finish
  • Standard industrial grey/optional custom colors
  • Noise Level
  • <75 dB(A) at 1 meter
  • Purification Stages
  • Multi-stage (Pre-filter, Activated Carbon, Molecular Sieve, etc.)
  • Inlet Gas Types
  • Nitrogen, Hydrogen, Oxygen, Argon, Helium, Compressed Air
  • Compliance Standards
  • ISO, CE, applicable industry standards
  • Operating Principle
  • Adsorption, Filtration, and Catalytic Reactions
  • Maintenance Requirements
  • Low, periodic filter/adsorbent media replacement
  • Ambient Operating Conditions
  • Indoor, dust-free environment
  • Installation Service
  • Available on request
  • Safety Features
  • Pressure relief valves, emergency shutdown, leak detection
  • Material of Construction
  • SS304/SS316 for wetted parts
 
 

About Gas Purification System

Gas Purification Systems

The RGP series of recirculating gas purification systems are complete stand-alone systems and are the main component of any inert atmosphere gas glovebox system. It is very compact and easily fits under the antechamber or the glove box.

It can achieve and maintaining a less than 1ppm H2O and O2



Advanced Multi-Stage Purification

Each gas purification system incorporates sequential stages-including pre-filtration, activated carbon treatment, and molecular sieve adsorption-to efficiently eliminate moisture, oils, hydrocarbons, and oxygen from process gases. This comprehensive approach ensures exceptional gas purity, supporting critical industrial applications requiring contamination control.


High Purity & Broad Compatibility

Delivering up to 99.999% outlet purity, this equipment is compatible with a range of gases such as nitrogen, hydrogen, oxygen, argon, helium, and compressed air. Suitable for industries where ultra-high purity is essential, the system accurately monitors purity with a digital LCD/LED display, enabling reliable quality assurance.


Compliance, Safety, and Ease of Use

Designed for strict compliance with ISO, CE, and applicable standards, the system includes safety features such as pressure relief valves, emergency shutdown, and leak detection. The modular configuration, low maintenance requirements, filter replacement indicators, and user-friendly automatic/manual controls ensure safe, reliable, and efficient operation.

FAQ's of Gas Purification System:


Q: How does the gas purification system remove contaminants from industrial gases?

A: The system uses a multi-stage process involving pre-filtration to capture particulates, activated carbon to trap oil and hydrocarbons, and molecular sieves for moisture adsorption. Additional catalytic and filtration steps further enhance purity, resulting in gas outlet purities up to 99.999%.

Q: What types of gases can be purified using this system?

A: This purification system is engineered to handle nitrogen, hydrogen, oxygen, argon, helium, and compressed air. It's adaptable to various industrial processes requiring specific gas qualities.

Q: When should maintenance be performed, and what does it involve?

A: Maintenance is straightforward and infrequent, requiring periodic replacement of filters and adsorbent media. Indicator alerts are integrated for timely servicing, and the equipment's low-maintenance design keeps downtime minimal.

Q: Where is the optimal installation site for this purification system?

A: For best results and longevity, install the gas purification system indoors in a dust-free environment. This ensures stable operation, accurate measurements, and reduces the risk of environmental interference.

Q: What is the benefit of using SS304/SS316 for wetted parts?

A: SS304/SS316 stainless steel offers excellent corrosion resistance and durability, especially when exposed to high-purity gases. This ensures the integrity of purified gas and extends the service life of the purification system.

Q: How is gas purity measured and displayed by the system?

A: Purity is monitored with integrated sensors and relayed to a digital LCD or LED display. The measurement devices have an accuracy of 1% of full scale, 0.01% resolution, and display results in less than 10 seconds, allowing for quick verification of gas quality.

Q: What are the advantages of the system's automatic and manual control options?

A: Users can operate the system in automatic mode for efficiency or select manual mode for customized control via PLC or touch panel. This flexibility aligns with varying process needs, offering both hands-off operation and precise manual adjustments as required.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Research/ Institutional Instrument Category

BIOREACTOR AND FERMENTOR

BIOREACTOR AND FERMENTOR

Price 400000 INR / Piece

Minimum Order Quantity : 01 Piece

Specimen Size : Customizable vessel/biomass

Number of Specimens : 16, as per vessel configuration

Response Time : < 5 seconds

Features : Automated sterilization, temperature, pH & DO control, agitation, data logging

CO2 INCUBATOR SYSTEM

CO2 INCUBATOR SYSTEM

Price 400000 INR / Piece

Minimum Order Quantity : 400000 Pieces

Specimen Size : Up to 150 mm height

Number of Specimens : Multiple (Custom adjustable)

Response Time : <30 sec

Features : Auto CO2 control, humidity display, overtemperature protection

GAS CHROMATOGRAPHY

GAS CHROMATOGRAPHY

Price 600000 INR / Piece

Minimum Order Quantity : 01 Piece

Specimen Size : Varies per vial, typically 1.52 ml

Number of Specimens : Single sample per run

Response Time : Detector: milliseconds

Features : Automatic ignition, Safety alarms, Data storage

High Speed Table Top and Floor Standing Centrifuges

High Speed Table Top and Floor Standing Centrifuges

Price 350000 INR / Piece

Minimum Order Quantity : 01 Piece

Specimen Size : 1.5 ml, 2 ml, 5 ml, 15 ml, 50 ml tubes compatible

Number of Specimens : 412 tubes per rotor (depending on rotor type)

Response Time : Immediate RPM adjustment

Features : Imbalance detection, automatic lid lock, programmable memory, brushless motor



Back to top