Gas Purification System
Gas Purification System

Gas Purification System

Price 1200000 INR/ Piece

MOQ : 01 Piece

Gas Purification System Specification

  • Interface Type
  • RS-485/Analog output (optional)
  • Port Size
  • 1/4 to 1 NPT/BSP (customizable)
  • Features
  • Modular design, easy maintenance, high efficiency, filter replacement indicators, automatic purge, corrosion-resistant material
  • Gas Pressure
  • 0.1 10 bar (as per user requirement)
  • Measuring Range
  • 099.99% Purity (Gas dependent)
  • Power Supply
  • 220-240V AC, 50/60 Hz, Single Phase
  • Equipment Type
  • Gas Purification System
  • Operating Voltage
  • 220-240V AC
  • Accuracy
  • 1% of full scale
  • Mounting Type
  • Skid mounted/Floor mounted
  • Display Type
  • Digital LCD/LED display
  • Frequency
  • 50/60 Hz
  • Resolution
  • 0.01% (purity metering)
  • Application
  • Removal of moisture, oil, oxygen, hydrocarbons, and other contaminants from industrial gases
  • Humidity
  • 5%-85% RH (non-condensing operational environment)
  • Max Height
  • 1200-2100 mm (varies per system capacity)
  • Automation Grade
  • Semi-Automatic / Fully Automatic (as configured)
  • Response Time
  • <10 sec (measurement devices only)
  • Temperature
  • 5C 40C (operating range)
  • Usage
  • Industrial gas purification (nitrogen, hydrogen, argon, oxygen, etc.)
  • Capacity
  • 10-200 Nm/hr (based on system design)
  • Machine Weight
  • Approx. 100-250 kg (varies by model complexity)
  • Control Mode
  • Automatic / Manual (via PLC or touch panel)
  • Purification Stages
  • Multi-stage (Pre-filter, Activated Carbon, Molecular Sieve, etc.)
  • Inlet Gas Types
  • Nitrogen, Hydrogen, Oxygen, Argon, Helium, Compressed Air
  • Material of Construction
  • SS304/SS316 for wetted parts
  • Compliance Standards
  • ISO, CE, applicable industry standards
  • Safety Features
  • Pressure relief valves, emergency shutdown, leak detection
  • Outlet Gas Purity
  • Up to 99.999% (based on application)
  • Installation Service
  • Available on request
  • Ambient Operating Conditions
  • Indoor, dust-free environment
  • Noise Level
  • <75 dB(A) at 1 meter
  • Operating Principle
  • Adsorption, Filtration, and Catalytic Reactions
  • Color/Finish
  • Standard industrial grey/optional custom colors
  • Maintenance Requirements
  • Low, periodic filter/adsorbent media replacement
 
 

About Gas Purification System

Gas Purification Systems

The RGP series of recirculating gas purification systems are complete stand-alone systems and are the main component of any inert atmosphere gas glovebox system. It is very compact and easily fits under the antechamber or the glove box.

It can achieve and maintaining a less than 1ppm H2O and O2



Advanced Multi-Stage Purification

Each gas purification system incorporates sequential stages-including pre-filtration, activated carbon treatment, and molecular sieve adsorption-to efficiently eliminate moisture, oils, hydrocarbons, and oxygen from process gases. This comprehensive approach ensures exceptional gas purity, supporting critical industrial applications requiring contamination control.


High Purity & Broad Compatibility

Delivering up to 99.999% outlet purity, this equipment is compatible with a range of gases such as nitrogen, hydrogen, oxygen, argon, helium, and compressed air. Suitable for industries where ultra-high purity is essential, the system accurately monitors purity with a digital LCD/LED display, enabling reliable quality assurance.


Compliance, Safety, and Ease of Use

Designed for strict compliance with ISO, CE, and applicable standards, the system includes safety features such as pressure relief valves, emergency shutdown, and leak detection. The modular configuration, low maintenance requirements, filter replacement indicators, and user-friendly automatic/manual controls ensure safe, reliable, and efficient operation.

FAQ's of Gas Purification System:


Q: How does the gas purification system remove contaminants from industrial gases?

A: The system uses a multi-stage process involving pre-filtration to capture particulates, activated carbon to trap oil and hydrocarbons, and molecular sieves for moisture adsorption. Additional catalytic and filtration steps further enhance purity, resulting in gas outlet purities up to 99.999%.

Q: What types of gases can be purified using this system?

A: This purification system is engineered to handle nitrogen, hydrogen, oxygen, argon, helium, and compressed air. It's adaptable to various industrial processes requiring specific gas qualities.

Q: When should maintenance be performed, and what does it involve?

A: Maintenance is straightforward and infrequent, requiring periodic replacement of filters and adsorbent media. Indicator alerts are integrated for timely servicing, and the equipment's low-maintenance design keeps downtime minimal.

Q: Where is the optimal installation site for this purification system?

A: For best results and longevity, install the gas purification system indoors in a dust-free environment. This ensures stable operation, accurate measurements, and reduces the risk of environmental interference.

Q: What is the benefit of using SS304/SS316 for wetted parts?

A: SS304/SS316 stainless steel offers excellent corrosion resistance and durability, especially when exposed to high-purity gases. This ensures the integrity of purified gas and extends the service life of the purification system.

Q: How is gas purity measured and displayed by the system?

A: Purity is monitored with integrated sensors and relayed to a digital LCD or LED display. The measurement devices have an accuracy of 1% of full scale, 0.01% resolution, and display results in less than 10 seconds, allowing for quick verification of gas quality.

Q: What are the advantages of the system's automatic and manual control options?

A: Users can operate the system in automatic mode for efficiency or select manual mode for customized control via PLC or touch panel. This flexibility aligns with varying process needs, offering both hands-off operation and precise manual adjustments as required.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Research/ Institutional Instrument Category

TOUCH SCREEN SPECTROPHOTOMETER

TOUCH SCREEN SPECTROPHOTOMETER

Price 900000 INR / Piece

Minimum Order Quantity : 01 Piece

Operating Voltage : 100240V AC

Features : Pass/Fail Analysis, Data Storage, Standalone Operation, Builtin Color Space Selection

Usage : Laboratory and Industrial

Control Mode : Touch Screen, Standalone or PC Software

ORBITAL SHAKER

ORBITAL SHAKER

Price 150000 INR / Piece

Minimum Order Quantity : 01 Piece

Operating Voltage : 220V AC 10%

Features : Antislip platform, continuous/interval shaking mode, maintenancefree motor

Usage : Laboratory sample mixing

Control Mode : Digital speed control

Universal High-Speed Centrifuge

Universal High-Speed Centrifuge

Price 350000 INR / Piece

Minimum Order Quantity : 01 Piece

Operating Voltage : 220V single phase

Features : Imbalance detection, safety lid lock, timer, automatic rotor recognition

Usage : Highspeed sample separation

Control Mode : Digital microprocessor control

Compound Microscope

Compound Microscope

Price 100000 INR / Piece

Minimum Order Quantity : 01 Piece

Operating Voltage : NA (manual, mirror for light)

Features : Coarse and fine focusing, rotating nosepiece, adjustable mirror

Usage : Observation of biological and prepared specimens

Control Mode : Mechanical



Back to top