Ion Chromatography
Ion Chromatography

Ion Chromatography

MOQ : 1 Piece

Ion Chromatography Specification

  • Measuring Range
  • 0.01 mg/L to 1000 mg/L
  • Specimen Size
  • 1-10 ml (injection volume)
  • Application
  • Detection and quantification of anions and cations in samples
  • Port Size
  • 1/8 inch (Standard)
  • Resolution
  • 0.001 mg/L
  • Display Type
  • Digital LCD
  • Automation Grade
  • Automatic
  • Temperature
  • Ambient, 5C to 40C
  • Mounting Type
  • Benchtop
  • Response Time
  • <10 sec
  • Power Supply
  • AC 220V, 50Hz
  • Operating Voltage
  • 220V AC
  • Frequency
  • 50/60 Hz
  • Humidity
  • Up to 85% RH, Non-condensing
  • Test Range
  • ppb to ppm levels
  • Gas Pressure
  • ---
  • Number of Specimens
  • 1 per run
  • Accuracy
  • 2%
  • Max Height
  • 500 mm
  • Hardness
  • ---
  • Features
  • Automatic eluent generator, In-built data storage, High sensitivity
  • Interface Type
  • RS232, USB
  • Usage
  • Water, food, and environmental analysis
  • Capacity
  • ---
  • Machine Weight
  • 45 Kg
  • Test Speed
  • Up to 8 ml/min
  • Test Width
  • ---
  • Test Stroke
  • ---
  • Control Mode
  • Microprocessor Based
  • Eluent Type
  • Compatible with carbonate/bicarbonate and other eluents
  • Column Type
  • Analytical Ion Exchange Column
  • Data Output
  • Chromatogram and quantitation reports
  • Equipment Type
  • Ion Chromatography
  • Pump Type
  • Dual piston pump
  • Software Included
  • Data acquisition and analysis software
  • Safety Interlocks
  • Over-pressure and leak detection
  • Power Consumption
  • 350 W
  • Flow Rate Stability
  • ±0.1% RSD
  • Detector Type
  • Conductivity Detector (suppressed/non-suppressed)
  • Sample Injector
  • Auto sampler support
  • Compliance
  • ISO 9001:2015 Certified
 

Ion Chromatography Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Week
  • Delivery Time
  • 30 Days
  • Main Domestic Market
  • Karnataka, All India
 

About Ion Chromatography

Banking upon in-depth domain knowledge and years of vast experience, we are engaged in offering Ion Chromatography. It is a range of innovative basic starter-line and highly customizable high-pressure ion analysis system. This system is used to separate charged particles from a liquid sample and measures its concentration.  It is developed to analyze particles such as anions, organic salts and proteins. Ion Chromatography is widely used in food, chemical and pharmaceutical laboratory. We offer this system at pocket friendly prices to clients.

Features:

 

 

  • High sensitivity conductivity detection
  • Isocratic high pressure system
  • Accurate and fine control of flow rates

 

 



Exceptional Flow Rate Stability

The dual piston pump maintains remarkable flow rate stability (0.1% RSD), ensuring consistent and accurate chromatographic results. This precision supports reliable quantitation and reproducible analysis, minimizing variations due to pump fluctuations. Users can achieve dependable separation and detection of ions, even at trace levels, optimizing method confidence and accuracy for regulatory and research needs.


Advanced Detection and Software Integration

This instrument is equipped with both suppressed and non-suppressed conductivity detectors, providing versatile detection capabilities for various ionic compounds. The included data acquisition and analysis software streamlines chromatography workflows, automates data handling, and simplifies report generation. Built-in data storage enables effortless archiving and traceability for quality control and compliance management.


Comprehensive Safety and Automation

Automated features such as an auto sampler and in-built eluent generator boost efficiency and workflow speed. Safety interlocksover-pressure and leak detectionensure operational protection, while the microprocessor-based control system delivers precise regulation and monitoring. The benchtop design and robust build (45 kg) make it ideal for laboratory environments, supporting high throughput and reliability in routine and demanding analyses.

FAQs of Ion Chromatography:


Q: How does the dual piston pump contribute to flow rate stability in ion chromatography?

A: The dual piston pump maintains a highly stable flow rate with a relative standard deviation of 0.1%, ensuring consistent eluent delivery during chromatography runs. This stability is crucial for reproducible ion separation, resulting in reliable quantitation and accurate chromatograms.

Q: What types of detectors are supported and what is their benefit?

A: This system provides both suppressed and non-suppressed conductivity detectors. Suppressed detectors enhance sensitivity and minimize background noise in anion analysis, while non-suppressed detectors offer flexibility for a wider range of ionic compounds. Together, these options maximize analytical scope and data quality.

Q: When should the auto sampler be used in analysis?

A: The auto sampler is ideal for workflows involving multiple samples or high-throughput testing. It automates specimen injection (110 ml per run), reducing manual intervention, increasing efficiency, and minimizing the risk of human error in routine water, food, or environmental analyses.

Q: Where can ion chromatography with this system be applied effectively?

A: This equipment is suited for laboratory settings engaged in water quality testing, food safety analysis, and environmental monitoring. Its robust design and automated features make it efficient for institutions requiring detection and quantification of anions and cations at ppb to ppm levels.

Q: What is the process for quantifying ions using this ion chromatograph?

A: Samples are injected (up to 1 specimen per run, injection volume 110 ml) via the auto sampler onto the analytical ion exchange column. Conductivity detectors identify and quantify ions, generating chromatograms and quantitative reports. The microprocessor-based system controls all critical parameters throughout the analysis.

Q: How does in-built data storage and software enhance user experience?

A: Integrated data storage and included acquisition/analysis software enable secure archiving of experimental data, automated processing, and simplified reporting. Users benefit from streamlined workflow, reliable documentation, and enhanced traceability, supporting regulatory and research requirements.

Q: What advantage does ISO 9001:2015 certification provide in this equipment?

A: ISO 9001:2015 certification assures users of the equipments quality management standards and compliance. It signifies rigorous manufacturing and operational processes, giving confidence in performance, reliability, and suitability for critical analytical applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Testing Instruments Category

Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection

Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection

Minimum Order Quantity : 1 Piece

Control Mode : Fully Automatic with Touchscreen Control

Usage : TOC measurement for high purity water

Power Supply : 230V AC, 50/60Hz

Features : High Sensitivity Detection, Automated Calibration, Data Logging, Password Protection, Intuitive User Interface

Simultaneous Thermal Analyzers

Simultaneous Thermal Analyzers

Price 2950000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Microprocessorbased

Usage : For simultaneous measurement of weight change and heat flow

Power Supply : 230V AC, 50/60 Hz

Features : Simultaneous DSC/TGA, Automatic gas flow control, Userfriendly interface

Kjeldahl Nitrogen Analyser

Kjeldahl Nitrogen Analyser

Price 700000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Automatic/Manual

Usage : Chemical analysis, protein determination

Power Supply : 230V AC, 50 Hz

Features : Automatic distillation, programmable temperature control, steam generator, safety features

Gas Detector Tube

Gas Detector Tube

Price 5000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Manual

Usage : Industrial safety, environmental monitoring, confined space entry

Power Supply : Not Required (Passive device)

Features : Singleuse, clear color change, simple operation



Back to top