Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection
Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection

Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection

MOQ : 1 Piece

Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection Specification

  • Application
  • Laboratory; Pharmaceutical; Semiconductor; Water Purity Analysis
  • Equipment Type
  • Total Organic Carbon Analyzer
  • Response Time
  • Within 3 minutes
  • Accuracy
  • ± 2% or better
  • Port Size
  • 1/4 inch
  • Power Supply
  • 230V AC, 50/60Hz
  • Humidity
  • 10% to 90% RH, non-condensing
  • Operating Voltage
  • 230V AC
  • Interface Type
  • USB, RS232, Ethernet
  • Display Type
  • Large Color Touchscreen LCD
  • Features
  • High Sensitivity Detection, Automated Calibration, Data Logging, Password Protection, Intuitive User Interface
  • Automation Grade
  • Fully Automatic
  • Max Height
  • 45 cm
  • Test Range
  • 0.2 ppb to 50 ppm TOC
  • Specimen Size
  • Minimum 5 mL sample volume
  • Temperature
  • 10°C to 35°C (operating)
  • Measuring Range
  • 0.2 ppb to 50 ppm Total Organic Carbon
  • Frequency
  • 50/60Hz
  • Number of Specimens
  • Single sample mode; autosampler optional
  • Resolution
  • 0.1 ppb
  • Gas Pressure
  • 60 psi (required for carrier gas)
  • Mounting Type
  • Benchtop
  • Usage
  • TOC measurement for high purity water
  • Capacity
  • Up to 60 samples with autosampler
  • Machine Weight
  • 20 kg
  • Control Mode
  • Fully Automatic with Touchscreen Control
  • Wetted Material
  • 316L Stainless Steel, PTFE
  • Languages Supported
  • Multi-Language (English, others available)
  • Safety Features
  • Over-temperature Protection, Leak Detection
  • Calibration Method
  • Automatic and Manual Multi-point Calibration
  • Maintenance
  • Low, with long-lasting catalyst and automated alerts
  • Detection Principle
  • High Temperature Catalytic Oxidation with NDIR Detection
  • Data Output Format
  • PDF, CSV, Printer compatible
  • Compliance Standards
  • USP, EP, JP, ASTM, ISO
  • Sample Introduction Method
  • Direct Injection or Autosampler
 

Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Week
  • Delivery Time
  • 30 Days
  • Main Domestic Market
  • Karnataka, All India
 

About Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection

We are a leading company specializing in the business of offering our clients Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection. It is designed to calculate the total organic compounds present in natural water and treated drinking water. We procure this analyzer from the trusted and certified vendors of the market with the help of our agents. The system uses combustion catalytic oxidation method to efficiently oxidize both easily-decomposed and hard-to-decompose insoluble organic compounds. Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection is used in pharmaceutical industry and water treatment system. 

Features:

  • Automatic dilution function
  • Space-saving and energy-saving design
  • Reliable sample injection system

 

 



Advanced Detection Principle

The Model Fusion employs high temperature catalytic oxidation paired with NDIR detection to reliably quantify total organic carbon, yielding high sensitivity down to 0.2 ppb. The system ensures rapid and accurate results for thorough water purity analysis.


Effortless Operation and Calibration

Operating the analyzer is straightforward through its large color touchscreen LCD. Automated and manual multi-point calibration options guarantee precision and ease of use, enabling efficient routine and controlled analysis. Maintenance stays minimal thanks to its robust, long-lasting catalyst and automated alert system.


Comprehensive Data Management

Data is easily managed through flexible output formatsPDF, CSV, or compatible printers. USB, RS232, and Ethernet interfaces allow for convenient integration with laboratory information systems, supporting compliance documentation and workflow optimization.


Safe and Durable Design

Safety is enhanced by over-temperature protection, leak detection, and construction from reliable wetted materials like 316L stainless steel and PTFE. The analyzers benchtop mounting and stable operation range foster risk-free usage across diverse laboratory settings.

FAQs of Total Organic Carbon Analyzer Model Fusion 0.2PPB Detection:


Q: How does the Model Fusion Total Organic Carbon Analyzer perform TOC measurements?

A: The analyzer utilizes high temperature catalytic oxidation combined with NDIR detection to quantify total organic carbon accurately in water samples, delivering reliable readings as low as 0.2 ppb.

Q: What sample introduction methods are supported by this analyzer?

A: This instrument accommodates direct injection for single samples and offers an autosampler option, enabling high-throughput analysis of up to 60 specimens in one sequence.

Q: When should recalibration be performed on the analyzer?

A: Recalibration can be scheduled automatically or conducted manually using its multi-point calibration system. Frequency depends on the applications quality control protocols and regulatory requirements.

Q: Where is the Model Fusion TOC Analyzer best utilized?

A: The analyzer is ideal for laboratory, pharmaceutical, semiconductor, and water purity analysis applications where accurate measurement of low-level TOC is critical.

Q: What are the benefits of the instruments safety and maintenance features?

A: Over-temperature protection and leak detection safeguard operators and the device, while the durable catalyst and automated alerts minimize maintenance efforts, ensuring long-term reliability.

Q: How does the data output format contribute to compliance and reporting?

A: Data output optionsPDF, CSV, and printer compatibilitystreamline result documentation and facilitate compliance with USP, EP, JP, ASTM, and ISO standards, simplifying audit preparation.

Q: What languages are supported by the control system?

A: The touchscreen interface offers multi-language options including English, allowing users in India and other regions to operate the analyzer efficiently.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Testing Instruments Category

CO2 Incubator with Built-in Roller or Shaker

CO2 Incubator with Built-in Roller or Shaker

Price 400000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Continuous CO2 incubation with agitation

Control Mode : Microprocessor PID control

Power Supply : 220V AC, 50/60 Hz

Features : Automatic UV sterilization, humidity tray, internal fan, data logging

Lab Vacuum Oven

Lab Vacuum Oven

Price 300000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Laboratory, Research Institutes

Control Mode : Microprocessor based PID Controller

Power Supply : 220 V AC, 50 Hz

Features : Double walled construction, toughened glass observation window, silicon gasket sealing

Roller bottle Incubator for rolling up to 90 bottles

Roller bottle Incubator for rolling up to 90 bottles

Price 800000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Continuous mixing and incubation

Control Mode : Digital Microprocessorbased

Power Supply : 220V AC, 50/60Hz, single phase

Features : Programmable speed and time, alarm system, temperature memory, CE certified

BIOSAFETY CABINET

BIOSAFETY CABINET

Price 300000 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Handling hazardous biological materials

Control Mode : Microprocessor control

Power Supply : AC 220V, 50Hz

Features : HEPA filter, UV sterilization, interlocked sashes, energy efficient



Back to top