UV VIS SPECTROPHOTOMETER
UV VIS SPECTROPHOTOMETER

UV VIS SPECTROPHOTOMETER

Price 250000 INR/ Piece

MOQ : 01 Piece

UV VIS SPECTROPHOTOMETER Specification

  • Resolution
  • 0.1 nm
  • Measuring Range
  • 0200% T, -0.3013A, 09999C (Absorbance, Transmittance, Concentration)
  • Frequency
  • 50 Hz
  • Mounting Type
  • Bench Top
  • Port Size
  • Standard 10 mm optical path cuvette
  • Power Supply
  • AC 220V 10%, 50Hz
  • Application
  • Quantitative & Qualitative Analysis in Chemistry, Biochemistry, Environmental, and Clinical Applications
  • Accuracy
  • 0.5% T
  • Temperature
  • Room Temperature (optimum 1035C)
  • Display Type
  • Digital LCD Display
  • Features
  • Automatic wavelength setting, Data storage, Self-calibration
  • Automation Grade
  • Semi-Automatic
  • Humidity
  • 85% RH
  • Specimen Size
  • 1 cm (cuvette width)
  • Number of Specimens
  • 1 at a time
  • Operating Voltage
  • 220 V
  • Equipment Type
  • UV VIS Spectrophotometer
  • Max Height
  • 180 mm
  • Test Range
  • 1901100 nm
  • Interface Type
  • RS232/USB
  • Response Time
  • Instantaneous (within 3 seconds)
  • Usage
  • Laboratory, Research, Industrial
  • Machine Weight
  • 13 kg
  • Control Mode
  • Automatic
  • Sample Holder
  • 4-position cuvette holder
  • Detector Type
  • Silicon Photodiode
  • Data Output
  • USB & Printer Port
  • Wavelength Accuracy
  • 0.5 nm
  • Spectral Bandwidth
  • 2 nm
  • Dimensions
  • 460 x 380 x 180 mm
  • Software Compatibility
  • Windows based interface
  • Stray Light
  • 0.3% T at 220 nm & 360 nm
  • Photometric Accuracy
  • 0.5% T
  • Lamp Life
  • 2000 hours (approx.)
  • Light Source
  • Deuterium Lamp (UV) & Tungsten Halogen Lamp (VIS)
  • Photometric Repeatability
  • 0.2% T
  • Wavelength Repeatability
  • 0.2 nm
  • Path Length
  • 10 mm
 
 

About UV VIS SPECTROPHOTOMETER

UV VIS Spectrophotometer

Steady, modern and elegant appearance design. Adopt the newest microcomputer technology and electronic control system. Optimized optical system and structure can both extend new functions and ensure the accuracy, stability and durability.



Advanced Optical Performance

Utilizing a deuterium lamp for UV analysis and a tungsten halogen lamp for visible spectrometry, this spectrophotometer delivers high resolution at 0.1 nm and accurate wavelength and photometric readings. The silicon photodiode detector ensures rapid response within 3 seconds, enabling high-throughput analysis with exceptional spectral precision (test range: 190-1100 nm).


User-Friendly Operation and Connectivity

The spectrophotometer incorporates a digital LCD display and features an intuitive, Windows-compatible software interface. Automatic wavelength setting, data storage capability, and USB/RS232 output ports streamline operation and ensure easy integration into laboratory workflows. Data reporting is simplified through a direct printer connection.


Versatile Sample Handling

Accommodating specimens with a standard 10 mm optical path, the spectrophotometer's 4-position cuvette holder allows efficient sample switching. With the capacity for 1 specimen at a time, it maintains high standards for repeatability and accuracy across diverse sample types, enhancing performance in both research and routine testing environments.

FAQ's of UV VIS SPECTROPHOTOMETER:


Q: How does the UV VIS spectrophotometer ensure accurate and repeatable measurements?

A: The device maintains accuracy through automatic wavelength setting, a spectral bandwidth of 2 nm, wavelength repeatability of 0.2 nm, and photometric repeatability of 0.2% T. Self-calibration and low stray light (0.3% T) further guarantee consistent results within 0.5% T accuracy.

Q: What types of samples and analytical applications is this spectrophotometer suitable for?

A: This spectrophotometer is designed for quantitative and qualitative analysis of samples in chemistry, biochemistry, environmental, and clinical applications. It supports concentration, absorbance, and transmittance measurements over a wide range with high sensitivity.

Q: When should the deuterium and tungsten halogen lamps be replaced?

A: Under typical usage, the deuterium and tungsten halogen lamps have a lifespan of approximately 2000 hours. It's recommended to schedule lamp replacement after this period or when performance indicators show weakening intensity or increased noise.

Q: Where can the spectrophotometer be operated most effectively?

A: Optimal operation is achieved in laboratory, industrial, and research settings at ambient temperatures between 10-35C with humidity levels not exceeding 85% RH. The bench-top mounting and compact dimensions (460 x 380 x 180 mm) suit standard lab environments in the United States.

Q: What is the process for sample analysis using this instrument?

A: Samples are placed in a standard 10 mm cuvette and loaded into the 4-position holder. The software guides the user through automatic wavelength selection, analysis, and data retrieval-making use of digital LCD display and rapid response (within 3 seconds) for easy, reproducible results.

Q: How does the spectrophotometer benefit laboratory and research productivity?

A: It streamlines workflows via automation features such as automatic wavelength adjustment and instant data output. Built-in data storage and connectivity (USB, RS232, printer) accelerate documentation and reporting, contributing to efficient, reliable, and high-throughput analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Research/ Institutional Instrument Category

Glove Box System

Glove Box System

Price 2100000 INR / Piece

Minimum Order Quantity : 01 Piece

Features : Air tight, Anticorrosive, Transparent window, Automatic purge

Usage : Controlled Atmosphere Handling

Power Supply : 220240 V AC, 50 Hz

Automation Grade : SemiAutomatic

BIOREACTOR AND FERMENTOR

BIOREACTOR AND FERMENTOR

Price 400000 INR / Piece

Minimum Order Quantity : 01 Piece

Features : Automated sterilization, temperature, pH & DO control, agitation, data logging

Usage : Industrial & laboratory fermentation and cell culture

Power Supply : 220V AC, 50 Hz

Automation Grade : Fully Automated

GAS CHROMATOGRAPHY

GAS CHROMATOGRAPHY

Price 600000 INR / Piece

Minimum Order Quantity : 01 Piece

Features : Automatic ignition, Safety alarms, Data storage

Usage : Qualitative and quantitative analysis

Power Supply : 230 V AC, 50/60 Hz

Automation Grade : SemiAutomatic/Automatic

UV TRANSILLUMINATOR

UV TRANSILLUMINATOR

Price 100000 INR / Piece

Minimum Order Quantity : 01 Piece

Features : Highintensity UV bulbs, uniform illumination, safety UV filter shield

Usage : Laboratory gel documentation and observation

Power Supply : 230V AC, 50 Hz

Automation Grade : Manual