Solvent Purification Systems Specification

  • Interface Type
  • Manual control valves, optional PLC interface
  • Automation Grade
  • Semi-automatic (fully automatic option available)
  • Power Supply
  • 220-240V AC, 50/60Hz
  • Temperature
  • 10C to 40C operating range
  • Equipment Type
  • Solvent Purification System
  • Humidity
  • Max. 80% RH non-condensing
  • Operating Voltage
  • 220-240V AC
  • Features
  • Modular columns, safety interlocks, inert operation, waste containment, explosion-proof design
  • Response Time
  • Immediate, continuous flow
  • Accuracy
  • Solvent output purity < 10ppm H2O/O2
  • Application
  • Removal of water/oxygen from organic solvents for laboratory use
  • Number of Specimens
  • Up to 6 solvent lines (standard), customizable
  • Display Type
  • Digital status indicators with LED
  • Max Height
  • 1550 mm
  • Port Size
  • 1/4 to 1/2 NPT
  • Specimen Size
  • Bottles up to 4L standard; customize on request
  • Mounting Type
  • Floor standing, heavy-duty castors
  • Gas Pressure
  • 4-7 bar (Nitrogen or Argon required)
  • Frequency
  • 50/60 Hz
  • Usage
  • Lab-grade solvent purification and dispensing
  • Capacity
  • Up to 150 L solvent reservoir
  • Machine Weight
  • Approx. 150 kg to 250 kg, depending on configuration
  • Test Speed
  • Standard solvent dispensing at 1-5 L/min
  • Control Mode
  • Automatic and manual modes available
  • Safety Features
  • Over-pressure protection, fire suppression port, automatic shutoff
  • Window Type
  • Acrylic inspection window for column status
  • Column Media
  • Highly activated alumina/sieves, replaceable
  • Solvent Compatibility
  • Suitable for THF, DCM, Toluene, Hexane, Acetonitrile, and more
  • Waste Liquid Handling
  • Integrated waste bottle connection
  • Solvent Lines Included
  • Up to 6 solvent purification columns
  • Construction Material
  • Stainless steel 304 housing, anodized aluminum panels
  • Bypass Function
  • Integrated for solvent selection and system purging
 
 

About Solvent Purification Systems

SPBT 1 Benchtop Solvent Purification System

Our SPBT 1 bench top solvent purifier is a compact yet complete system for safely drying solvents and was specifically designed to fit on a bench top or under a fume hood.


SP 1 Standalone Solvent Purification System

SP 1 standalone solvent purifier is a complete system built from the highest quality components available and has the capacity to handle up to seven (7) different solvents. The system delivers pure anhydrous solvent using a safe and reliable process. No more dangerous solvent stills.



Advanced Construction and Safety

Featuring durable stainless steel 304 housing and anodized aluminum panels, this system is engineered for longevity in active laboratory settings. The explosion-proof design, integrated fire suppression port, and over-pressure protection guarantee user safety during operation. Heavy-duty castors make repositioning convenient, and the acrylic inspection window allows visual monitoring of column status.


Versatile Solvent Purification

The system supports up to six purification columns that are easily replaceable and compatible with a wide array of solvents, including THF, DCM, Toluene, Hexane, and Acetonitrile. Purification media efficiently remove water and oxygen impurities, achieving output purities of less than 10 ppm. Users can tailor their setup based on workflow requirements and solvent choices.


User-Friendly Control and Maintenance

Operation is simplified with both manual and automatic modes, while digital LED status indicators provide real-time feedback. A built-in bypass function allows for rapid solvent selection and system purging. Maintenance is streamlined with modular columns and integrated waste bottle connections for safe disposal of residues. Optional PLC interfaces further enhance automation and remote monitoring.

FAQ's of Solvent Purification Systems:


Q: How does the Solvent Purification System ensure high purity of solvents?

A: The system uses highly activated alumina/sieves in its modular columns to efficiently remove water and oxygen. This process reduces contaminants to less than 10 ppm, meeting the stringent requirements of sensitive laboratory applications.

Q: What safety features are included to protect users during operation?

A: Safety is maximized with over-pressure protection, fire suppression port, automatic shutoff, and a robust stainless steel housing. Additionally, safety interlocks and explosion-proof design further minimize risks associated with purified solvent handling.

Q: When should the column media be replaced in the system?

A: Column media should be replaced periodically or when digital status indicators show a decline in purification efficiency. The modular design makes replacing columns straightforward, ensuring consistent solvent purity.

Q: Where can this solvent purification system be installed?

A: Its floor-standing design with heavy-duty castors allows flexible placement in laboratories, research institutions, and industrial environments across the United States. It is best situated in well-ventilated areas with compatible power and gas supplies.

Q: What solvents are compatible with this purification system?

A: The system is compatible with common laboratory solvents, including THF, DCM, Toluene, Hexane, and Acetonitrile. Customization options enable use with additional solvents as needed.

Q: How is waste liquid managed in the purification process?

A: Waste liquid from purification is safely contained via an integrated waste bottle connection, preventing contamination and promoting safe disposal in compliance with laboratory protocols.

Q: What are the main benefits of using this system in a laboratory setting?

A: Key benefits include reliable and rapid solvent dispensing, modular configuration for up to six solvent lines, high purity output, robust safety measures, and user-friendly automated operation. This system enhances workflow efficiency and maintains consistent solvent quality for advanced research.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Research/ Institutional Instrument Category

MANUALCOLONY COUNTER schuett count

MANUALCOLONY COUNTER schuett count

Price 250000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Manual operation with pressuresensitive counting pen

Usage : Microbial colony enumeration

Features : Acoustic and visual signals; adjustable background illumination; pressuresensitive pen; easy dish rotation

Automation Grade : Manual

REFRIGERATED INCUBATOR WITH BUILT IN SHAKER

REFRIGERATED INCUBATOR WITH BUILT IN SHAKER

Price 400000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Digital PID Temperature & Speed Control

Usage : Laboratory

Features : Programmable Timer, Overtemperature protection, Safety Door Switch, Uniform Air Circulation

Automation Grade : Fully Automatic

Data Apex- Clarity Chromatography Software

Data Apex- Clarity Chromatography Software

Price 200000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Softwarebased instrument control; multiple hardware modules supported

Usage : Chromatographic data acquisition, analysis and management

Features : Multilingual, multiinstrument control, audit trail, customizable reports, method validation tools, automation support

Automation Grade : Fully automatic data handling, method automation possible

Gas Purification System

Gas Purification System

Price 1200000 INR / Piece

Minimum Order Quantity : 01 Piece

Control Mode : Automatic / Manual (via PLC or touch panel)

Usage : Industrial gas purification (nitrogen, hydrogen, argon, oxygen, etc.)

Features : Modular design, easy maintenance, high efficiency, filter replacement indicators, automatic purge, corrosionresistant material

Automation Grade : SemiAutomatic / Fully Automatic (as configured)



Back to top