Bench Top Fermentor and Bioreactor System
Bench Top Fermentor and Bioreactor System

Bench Top Fermentor and Bioreactor System

Price 400000 INR/ Piece

MOQ : 01 Piece

Bench Top Fermentor and Bioreactor System Specification

  • Features
  • Sterilizable in place (SIP), autoclavable, real-time monitoring, data logging, adjustable agitation and aeration, jacketed vessel for temperature control
  • Application
  • Microbial cell culture, fermentation process research, biotechnology, pharmaceuticals
  • Frequency
  • 50/60 Hz
  • Accuracy
  • pH sensor: 0.02 pH; DO sensor: 2%
  • Humidity
  • Ambient
  • Max Height
  • Approx. 600800 mm (varies with model)
  • Automation Grade
  • Fully automatic
  • Mounting Type
  • Table top / Bench top
  • Port Size
  • Multiple standard ports (6 mm, 8 mm, 12 mm) for sensors and sampling
  • Temperature
  • Ambient to 70C (PID controlled)
  • Measuring Range
  • DO: 0200%; pH: 014
  • Display Type
  • Color touch screen and digital display
  • Interface Type
  • USB, RS232, Ethernet
  • Gas Pressure
  • 0.20.4 MPa (Air supply for aeration)
  • Equipment Type
  • Bench Top Fermentor and Bioreactor System
  • Test Range
  • Typically 0.520 L working volume
  • Power Supply
  • 220V/50Hz single phase AC
  • Response Time
  • <20 seconds for sensors
  • Operating Voltage
  • 220V
  • Resolution
  • 0.01 unit for pH, 0.1% for DO
  • Usage
  • Laboratory fermentation, pilot studies, educational purposes
  • Capacity
  • 1, 3, 5, 7, 10, or 20 liters (working volume)
  • Machine Weight
  • Approx. 30-40 kg
  • Test Speed
  • Up to 1000 rpm (Agitation Speed)
  • Control Mode
  • Touch screen PLC or SCADA system
  • Sterilization Method
  • Autoclavable or in-situ sterilization options
  • Compatible Media
  • Supports all standard fermentation and cell culture media
  • Exhaust System
  • Sterile exhaust condenser
  • Lighting
  • LED/lamp option for phototrophic cultures (on request)
  • Agitation Shaft
  • Stainless steel, removable
  • Noise Level
  • <60 dB
  • Sensor Ports
  • Dedicated ports for pH, DO, temperature, foam, level
  • Alarm System
  • Audio/visual for critical parameter thresholds
  • Agitator Type
  • Magnetic or mechanical drive (top or bottom mounted)
  • Aeration System
  • Sintered sparger with rotameter-controlled air/oxygen supply
  • Stirrer Seal
  • Low maintenance mechanical seal
  • Cooling System
  • Water jacket / external chiller compatible
  • Vessel Material
  • Borosilicate glass with stainless steel (SS 316/SS 304) fittings
 
 

Bench Top Fermentor and Bioreactor System About

Interface main control screen configuration so that calibration of pH, DO , temperature and bubble detection sensor can be handled simply .The program is applied to suit various culture environments and can be used simply. It has a compact design to enable various culture experiments even in a small laboratory. A self-diagnosis system that can record and maintain the fermentation process is applied, and it can be used by connecting to a PC for real-time recording and control. Controllable by easily connecting an external device to the fermenter controller.

Advanced Vessel and Agitation Design

The system incorporates a high-quality borosilicate glass vessel with corrosion-resistant stainless steel fittings, ensuring long-term reliability and purity. Users can choose between magnetic or mechanical drives for optimal agitation tailored to specific culture requirements. Both top- and bottom-mounted setups are available, supporting various research and pilot scale processes.


Precision Control and Real-Time Monitoring

Equipped with dedicated sensor ports for pH, DO, temperature, and foam, the system facilitates continuous monitoring of key process parameters. The color touch screen PLC supports data logging, adjustable agitation (up to 1000 rpm), and audio-visual alarms to safeguard your cultures under changing conditions. Researchers benefit from enhanced process control and reproducibility.


Optimized Aeration and Sterilization

Sintered sparger with rotameter-regulated air/oxygen supply ensures efficient aeration. Sterilization is convenient and versatile - vessels can be autoclaved or sterilized in place (SIP), saving time and reducing contamination risk. The sterile exhaust condenser further maintains a safe operating environment, meeting the stringent demands of laboratory and pilot fermentations.

FAQ's of Bench Top Fermentor and Bioreactor System:


Q: How do I sterilize the Bench Top Fermentor and Bioreactor System, and which methods are supported?

A: The system supports both in-situ sterilization (SIP) and conventional autoclaving, allowing you to choose either method based on your workflow and safety needs. The autoclavable vessel and fittings, along with a low-maintenance mechanical stirrer seal, streamline regular cleaning and sterilization processes.

Q: What type of agitation and aeration can I expect with this bioreactor?

A: This bioreactor supports both magnetic and mechanical drive agitation, with top or bottom mounting to suit different culture types. Aeration is delivered through a sintered sparger and controlled by a rotameter, allowing precise air or oxygen supply for optimal microbial or cell growth.

Q: When should I use lighting for the vessel, and what options are available?

A: Lighting is recommended for phototrophic cultures that require controlled light exposure. On request, the system can be equipped with LED or lamp options to support such research applications in microbiology or plant cell studies.

Q: Where can I use this Bench Top Fermentor and Bioreactor System?

A: The system is designed for laboratory bench top use, suitable for academic research, pilot studies, biotechnology laboratories, and pharmaceutical development. Its moderate footprint and weight make it ideal for institutions requiring flexible, portable bioprocess solutions.

Q: What are the benefits of the integrated sensor ports and real-time control?

A: Dedicated sensor ports for pH, dissolved oxygen (DO), temperature, foam, and level enable accurate and continuous monitoring. The real-time data display and logging functions facilitate precise control over your fermentation processes, improving reproducibility and experiment efficiency.

Q: How does the cooling and exhaust system improve experimental safety and performance?

A: The water jacket or external chiller compatibility allows consistent temperature control, vital for sensitive cultures. The sterile exhaust condenser maintains a contaminant-free environment within the bioreactor, protecting both product integrity and operator safety.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Testing Instruments Category

Ion Chromatography

Ion Chromatography

Minimum Order Quantity : 1 Piece

Usage : Water, food, and environmental analysis

Control Mode : Microprocessor Based

Features : Automatic eluent generator, Inbuilt data storage, High sensitivity

Orbital Shaker

Orbital Shaker

Price 300000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Laboratory shaking, mixing

Hardness : Corrosion resistant platform

Control Mode : Digital control with touch pad

Features : Variable speed, timer, quiet operation, antislip platform

Latest Technology Ultrapure Water System

Latest Technology Ultrapure Water System

Price 300000 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Ultrapure water production

Hardness : Adjustable via pretreatment stage

Control Mode : Microprocessor based automatic control

Features : Touch screen, automatic maintenance alerts, integrated pretreatment and polishing

Gas Detector Tube

Gas Detector Tube

Price 7000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial safety, environmental monitoring, confined space entry

Hardness : Glass material, standard lab hardness

Control Mode : Manual

Features : Singleuse, clear color change, simple operation



Back to top